Skip to main content
Skip to main content
Find answers for your product

ERR. 02 error is displayed on the Edel cylinder. What does this mean?

Article reference KA-01830


This means the Edel had detected one of the following possible issues:
- Discrepancy between the air, water & evaporator temperatures
 - The hot water or air temperature sensors might be misreading or accidentally swapped around

An engineer’s visit will be needed to establish root cause & repair.

Take following parts (applies to all sizes):
X-B1244575 (Hot water temp probe 10kOhm 1200mm)
X-B4993072 (Evap temp probe 10kOhm 900mm)
X-B1244090 (Air temp probe 10kOhm 460mm)
X-B1244096 Main PCB

 

Note: It is impossible to ask for the backup to run if there is an ERR02 fault as the hot water temperature is suspect and cannot be relied upon to control the immersion element.






Applicable Models:

EDL170-520, EDL170-520RF, EDL200UK-630, EDL200UK-630RF, EDL270UK-630, EDL270UK-630RF

Was this article helpful?

Need more help? Contact our support team