Clock error is displayed on the Edel cylinder. What does this mean?

Article reference KA-01826

This is an error with the display or main PCB accessing the onboard timeclock function. 

The user should try setting the current date & time by pressing the clock button on the display, then setting the date/time correctly. 

Watch on Vimeo

Edel Clock Nov 2019 from GDHV Digital on Vimeo.


If the error persists, a competent engineer should isolate the mains supply as per safe isolation procedure, then change the display and/or Main PCB to resolve the issue. Both display & PCB should be taken to the job.

500002222 170l cylinder display & cable
X-B4992570 200 & 270L cylinder display & cable
X-B1244096  Main PCB (all 3 sizes) 


The compressor should still work providing the timer is set to 0000-2400 COMF mode (see page “Programming” section in the user manual) but if the compressor does not run, electric backup mode can be selected:
 

To switch on the backup immersion, search knowledge base “My Edel hot water cylinder has stopped heating the water. How do I get hot water via backup?”






Applicable Models:

EDL170-520, EDL170-520RF, EDL200UK-630, EDL200UK-630RF, EDL270UK-630, EDL270UK-630RF