Skip to main content
Skip to main content
Find answers for your product

Quantum Series G showing error code 001. What does this mean?

Article reference KA-01553

If the error occurs within 2 mins of the heater being powered on, it means the core temperature sensor is misreading.

Take Part 10855G & QMKIT2 as it could be the Core Temperature sensor or the Charge Controller at fault.

DO NOT SEND JUST THE CHARGE CONTROLLER NEEDS TO BE COMPLETE QMKIT2 due to software compatibility.

If the error occurs after 2 mins or it randomly happens after some time, this suggests a software issue. Engineer to attend with part QMKIT2.


In guarantee, please submit a ticket.

If out of warranty, contact nearest service agent to attend see additional help link for list of service agents below.

Applicable to: QM050 QM070 QM100 QM125 QM150






Was this article helpful?

Need more help? Contact our support team