Skip to main content
Skip to main content
Find answers for your product

What happens to the ECOTi tubular heater after a power cut?

Article reference KA-02721

Power outage

The ECOTi has a memory backup of 3-4 days via a supercapacitor, which stores the previous operation settings.

Following a complete loss of power to the product and depending on the last mode it was operating in, the following controller behaviour would be expected when power returns:

 

MANUAL ON 

The product returns to MANUAL ON at the temperature that was previously set.

 

MANUAL OFF 

The product will remain in MANUAL OFF.

 

AUTO 

The controller will ask for the time to be set for 20 seconds, if not set the product will go to MANUAL ON at 10°C. Upon activating the screen again, or if switching to this mode after a power outage, the product will ask for the clock to be set before giving heat again.

 

Standby 

The product will return to Standby

 

Applicable Models 

ECOTi1FT, ECOTi2FT, ECOTi3FT, ECOTi4FT, ECOTi5FT, ECOTi6FT

Was this article helpful?

Need more help? Contact our support team